Retail Pro™ Single Leaf Manually Operated Horizontal Sliding Door
DWG Approval DrawingApproval DrawingsInstallations Instructions

Retail Pro™ Single Leaf Manually Operated Horizontal Sliding Door

Designed specifically for the needs of the retail industry.

Features
  • Diamond-Trac® Roller System: This patented system elicits rave reviews from industry experts and customers. It permits a smooth, quiet gliding action unrivaled in any door of its type. Its superior sealing ability is due to its down-and-in motion that pushes the door tightly against the gasketed casing and floor.
  • Freezer or cooler
  • White Metal clad finish
  • Available with bump open bar
  • Kickplates and edge guard options
  • One Year Limited Warranty

Plyfoam I® Swing Doors

Cooler Door Specifications:

Supply where indicated on plans Jamison Plyfoam® Track Cooler Door.

Door panel to be constructed of #26 gauge white pre-painted stucco embossed steel pans front and back with reinforcement for hardware attachment. Frame metal clad on all exposed surfaces with #26 gauge white pre-painted stucco embossed steel.

All metal cladding to be applied in accordance with M.I.D., USDA regulations.

Door to be filled with 4″ of Jamifoam non-CFC polyurethane insulation with an R value of 28 at 40° F.

Gasket at sides and head of door lip to be grease resistant synthetic skin with resilient sponge core, sill gasket to be sweep type.

Plyfoam I® Swing Doors
ADS SheetApproval DrawingsInstallation Instructions

Hardware to have protective coating against corrosion and to consist of adjustable spring hinges and safety release type fastener (permits door to be opened from inside even though padlocked on front). (Note: For door sizes over 5’0″ wide, specify – door to be equipped with safety release device.) Track port opening shall be closed with rubber flaps that will permit passage of trolley rollers and gambrels. Flaps to be field notched around track by installing contractor.

Freezer Door Specifications:

Freezer door specifications to be same as cooler door except for these substitutions and additions:

Supply where indicated on plans Jamison Plyfoam® Track Freezer Door.

All metal cladding on warm side of door (front unless otherwise specified) and frame shall be applied with all seams and penetrating bolts sealed.

Provide Frostop heater cables in the sides, head, and sill of the frame at gasket contact areas. Complete device to be assembled, ready for connection to 120 volt, 60 Hertz, single phase AC line.

Special Notes:
  1. When cold room temperature is below -20° F. or temperature difference is more than 90° F., contact factory.
  2. If freezer door must be mounted in freezer room, please contact factory for recommendations.
Available in Fiberglass

Constructed of Fiberglass for use in harsh environments such as food processing. Contact factory for more information

ADS 201Approval DrawingsInstallation Instructions

Mark IV™ Single Leaf Horizontal Sliding Manually Operated Door

Jamison’s most popular door offers unique designs, features and benefits that keep it in high demand throughout the industry.

Our standard door panel and face casing are woodless.

Features
  • Diamond-Trac® Roller System: This patented system elicits rave reviews from industry experts and customers. It permits a smooth, quiet gliding action unrivaled in any door of its type. Its superior sealing ability is due to its down-and-in motion that pushes the door tightly against the gasketed casing and floor.
  • Extruded aluminum door frame: Provides strength superior to wood.
  • Versatile: Designed to handle applications up to a 100F delta T, and available with many options.
  • Standard panels: White, stucco-embossed #26 gauge galvanized steel, front and back.
  • Gaskets: Tear resistant adjustable frame gaskets.
  • Flexibility: Closer positioning of doorways also provides critical floor and wall space savings.
  • Easy Installation: With track and angles preassembled on our casings, installation is quick and easy.
  • 5-year limited warranty

Options & Accessories
  • Metal cladding can be stainless steel, stucco aluminum, galvanized stucco embossed, galvanized, or galvanized steel painted to meet specifications.
  • M.I.D. Requirements.
  • Padlocking provisions on front or back of door with safety release on opposite side. (Specify which side with locking.) Safety release feature permits door hardware to be released, thus minimizing possibility of personnel being locked in room.
  • 6″ of insulation for freezer door (R value 42).
  • Swinging wicket door.
  • View windows: (contact factory for specific recommendations.) 12″ x 14″ sealed glass unit.
    1. Cooler Door – 2 layer 1″ thick
    2. Freezer Door – 3 layer, 1′ thick with heat.
  • Jambs.
  • Inside trim.
  • Mirror image frame.
Cooler Door Specifications

Supply where indicated on plans Jamison Mark IV® Manual Single Leaf Horizontal Sliding Cooler Door, with Diamond-Trac® System*.

Door leaf to have aluminum extruded structure and to be metal clad with #26 gauge white pre-painted stucco embossed steel front and back.

Frame (casings and header) to be constructed of aircraft quality aluminum extrusions with white painted finish.

Door leaf to be filled with 4″ of Jamifoam non-CFC polyurethane insulation with an R value of 28 at 40°F. Frame to be insulated with polystyrene inserts.

Adjustable gasket at sides and head of frame to be polyester reinforced; sill gasket on door to be sweep type.

Hardware to have protective coating against corrosion.

Freezer Door Specifications

Freezer door specifications to be same as cooler door except for these substitutions and additions:

Supply where indicated on plans Jamison Mark IV® Manual Single Leaf Horizontal Sliding Freezer Door with Diamond-Trac® System*.

Provide Frostop heater cables in top, sides, and bottom of door. Complete device to be assembled, ready for connection to 120 volt, 60 Hertz, single phase AC line.

Special Notes:
  1. Freezer Door is designed for installation in warm room with temperatures above +33°F. If door must be mounted in rooms with temperatures of +32°F. and below, contact factory.
  2. When cold room temperature is below -20°F. and /or the relative humidity is greater than 80% on the warm side, Frostop heater cables should be added to the frame/gasket assembly.
  3. If the cold room temperature is below -40°F., or if the temperature difference exceeds 90°F., contact factory.

Hybrid: AC & CAC with Roll-up Doors

By combining an air door with your currently installed door, you are assuring an efficient air block when your hard door is open, reducing cold air loss and decreasing the problems associated with high-traffic openings, such as ice and safety concerns.

Features
  • Maximizes the energy efficiency of a roll-up door
  • Effectively reduces moisture infiltration
  • Significantly reduces air exchange between rooms of differing temperature
  • HCR Model AC and CAC is retrofitable to existing roll-up doors of any brand
  • Additional air doors can be added in a modular process to keep maximizing energy efficiency as door open time increases
  • Warm side or Cold side mounts

Hybrid AC & CAC with VersaFlex™

Achieve the next level of efficiency by adding an HCR Model AC or CAC to your existing door. Perfect for high-traffic doorways where ice and infiltration are a challenge, an HCR Air Door provides another layer of protection to assure that the opening remains accessible for workflow, yet closed for costly air infiltration and energy efficiency.

Features
  • Maximizes the energy efficiency of an insulated Hittable Bi-Parting or Single Sliding Door
  • Significantly reduces moisture infiltration
  • Significantly reduces air exchange between rooms of differing temperature
  • AC and CAC is retrofitable to existing Bi-Parting or Single Sliding Doors
  • Additional air doors can be added to keep maximizing energy efficiency
  • Warm side or cold side mount

Model 3CAV Triple Conditioned Air Vestibule

The Model 3CAV is primarily used between rooms with extreme temperature differences and very high traffic.

The frost elimination cycle is similar to the Model DCAV but the additional vestibule improves efficiency as well as increases the model’s temperature range applicability.

The Model 3CAV automatically adjusts as conditions change to optimize performance and reduce energy consumption.

With the use of HCR sensors and software, Model 3CAV can be integrated into a facility’s refrigeration control and monitoring system.  This allows both remote monitoring and remote adjusting of the HCR equipment.

Features
  • Wide open doorway
  • No frost, fog or icing
  • Reduced moisture gains
  • Reduced refrigeration loss
  • Reduced coil defrosting burden
  • Eliminates safety hazards
  • No haze within cold room
  • Reduced maintenance costs
  • No frost on stored products
  • Increased warehouse productivity
  • Improved refrigeration cycle efficiency
  • Sublimates existing frost build-up
Options & Accessories
  1. Metal cladding can be stainless steel or cold-rolled steel powder coated to custom color.
  2. ‘Clean outs’ can be added where needed.
  3. Complete NEMA 3, 4, 4x, 4x stainless, or 12 requirements.
  4. Hot Gas Coil instead of resistive heat.
  5. Custom standoff panels with trim to interconnect to night doors or existing doors.
  6. HCR Air Door to be used in conjunction with existing or new door to form a Hybrid solution. These doors can include all types of insulated roll up doors, double curtain roll up doors, hard insulated automatic doors that slide either horizontally or vertically, or insulated sliding mattress type doors.

Specifications:

Triple Conditioned Air Curtain Vestibule, Freezer to Ambient Specifications:

Supply where indicated on plans HCR Model 3CAV Air Vestibule for doorways between Freezers and Coolers or ambient.

Air Door to be powder coated cold-rolled steel. Powder coating meets 500 hour salt spray test.

NEMA 1 Power/control panel complete. Model 3CAV equipment cabinet houses the centrifugal fan and prewired electrical components. Service door(s) are provided, if required, to allow access to all internal components. Motor is controlled by VFD (Variable Frequency Drive). Single point electrical power connection in most cases.

Model 3CAV to have six side plenums: three with discharge nozzle, the other three with an intake.

Discharge nozzle is easily adjustable to maximize air block. Air volume adjustment mechanisms are easily accessible without removing any covers or secondary openings.

Unit can be mounted on either side of wall. Depending on temperature differential insulation cladding may be required.

Air Door assembly is structurally self-supporting. All hardware has protective coating against corrosion.

Air Door power to be 208, 240, or 480 volt AC, 60 Hertz, 3 phase. Visible signal light to show when motor is not running. Complete door assembly to be ready for connection to power. (Architect to designate responsibility for field wiring.)

Freezer Door Specifications:

Supply where indicated on plans HCR Model 3CAV for freezer doorways with temperature differentials greater than 40 degrees Fahrenheit. Provide insulation cladding as may be required for the specific application.

Air Doors forming Model 3CAV can be mounted either on the warm side or the cold side of the wall or split mounted.

Electric resistive heat or waste heat reclaim as required.

ASSD Fast-Acting Traffic Door

ASSD Fast-Acting Traffic Door

The Model ASSD is a swift opening and closing motorized strip-door.  Strip-door operation is easily adjusted to suit traffic speed.

Features
  • May be mounted inside the doorway or within the door jamb
  • Recommended for doorways subjected to infiltration due to temperature differences
  • Fully-lapped fixed strips retain 95% effectiveness
  • Clear plastic strips significantly outlast push-through strips
  • For negative pressure applications under
  • 1 MPH flow-through velocity
  • Can be used between 2 freezers without requiring any heat